Moxa IOLOGIK E4200 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Controladores de energia remotos Moxa IOLOGIK E4200. Moxa ioLogik E4200 [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 105
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
ioLogik Active Ethernet Modular I/O
Users Manual
Second Edition, May 2009
www.moxa.com/product
© 2009 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
Vista de página 0
1 2 3 4 5 6 ... 104 105

Resumo do Conteúdo

Página 1 - User’s Manual

ioLogik Active Ethernet Modular I/O User’s Manual Second Edition, May 2009 www.moxa.com/product © 2009 Moxa Inc. All rights reserved. Reproduction

Página 2

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-6Dimensions Network Adaptor (Unit:mm)/(WxHxD: 45 x 99.8 x 70 mm)

Página 3 - Table of Contents

ioLogik Active Ethernet Modular User’s Manual SNMP MIB File E-3UDP MIB TCP MIB SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRt

Página 4

ioLogik Active Ethernet Modular User’s Manual SNMP MIB File E-4Private MIB File and SNMP Variables Moxa also provides an SNMP for the I/O MIB file t

Página 5 - Introduction

ioLogik Active Ethernet Modular User’s Manual SNMP MIB File E-5 moduleName9 moduleName10 moduleName11 ioType9 ioType10 ioType11 numberOfChannels9 nu

Página 6 - Active Ethernet Modular I/O

FF Appendix F. Factory Default Settings The ioLogik E4200 is configured with the following default private IP addresses: LAN-0 Default IP address:

Página 7 - Product Features

ioLogik Active Ethernet Modular User’s Manual Factory Default Settings F-2Modbus Addressing Mode: Fixed mode Click&Go Power-on Status: Stop

Página 8 - Product Specifications

GG Appendix G. FCC FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) Thi

Página 9

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-7I/O Module (Unit: mm; W x H x D: 14 x 99.8 x 70 mm)

Página 10 - Dimensions

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-8Hardware Reference Panel Guide NOTE: The reset button restarts the s

Página 11

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-9Hardware Specifications LAN Ethernet 2 x10/100 Mbps, RJ45 Protection: 1.5 KV magn

Página 12 - Hardware Reference

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-10LED Indicators for Network Adaptor Group Pins/Description Printed label Ethernet

Página 13 - Hardware Specifications

22 Chapter 2. Initial Setup This chapter includes explains how to install the ioLogik Active Ethernet modular I/O including the Ethernet network a

Página 14

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-2System Architecture The ioLogik E4200 modular I/O consists of a network adaptor th

Página 15 - Initial Setup

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-3Installing the I/O Module on a DIN-Rail Step1: Align the I/O module side by side w

Página 16 - System Architecture

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-4Removing the I/O Module from the DIN-Rail Step1: Use your finger or a screw driver

Página 17

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-5Remove the RTB (Removable Terminal Block) from the I/O module Pull out the plastic

Página 18

ioLogik Active Ethernet Modular I/O User’s Manual The software described in this manual is furnished under a license agreement, and may be used onl

Página 19

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-6Installing the System Power Module The system power expansion module is designed t

Página 20 -

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-7Installing the Field Power Module The field power distributor is designed to isola

Página 21

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-8Connecting the Power System Two 24 VDC power sources are required to power the ioL

Página 22 - Connecting the Power System

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-9Connecting to the Network ioLogik E4200 Active Ethernet Network Adaptor The ioLogi

Página 23 - Connecting to the Network

ioLogik Active Ethernet I/O Family User’s Manual Initial Setup 2-10Configuring Your Network Architecture The most important thing is configuring you

Página 24

33 Chapter 3. Utilities This chapter introduces software utilities you can use when configuring the ioLogik Active Ethernet modular I/O system. Th

Página 25 - Utilities

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-2This chapter introduces software utilities you can use when configuring the Windows-ba

Página 26 - Features of Modular ioAdmin

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-3Import/Export files: There are three files that can be generated by Modular ioAdmin au

Página 27 - Getting Starting

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-4Connecting Your Active Modular I/O System After you open Modular ioAdmin, the auto sea

Página 28

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-5 ATTENTION If there are multiple network interfaces in the host computers, be sure to

Página 29

Table of Contents Chapter 1. Introduction ...1-1 ioLogi

Página 30

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-6Continue: If you have just added new I/O modules onto the end of the existing I/O syst

Página 31 - Functions on Menu Bar

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-7Wiring Guide Modular ioAdmin provides a wiring guide to the ioLogik Active Ethernet mo

Página 32

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-8System Several operations are possible from the System menu. Auto Scan Active Ethernet

Página 33 - Server Context Menu

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-9Navigation Panel In this panel, Modular ioAdmin will show you the information for the

Página 34 - Main Window (General)

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-10Restart System (Administrator Function) Select this command to restart your ioLogik I

Página 35 - Administrator Functions

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-11Adaptor Settings Tab (General) The Adaptor Settings tab is where you log in as an adm

Página 36 - I/O Status

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-12I/O Configuration Tab (Administrator) When logged on as an administrator, you may cli

Página 37 - Safe Status Settings

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-13Config (For output modules only) The list in this tab shows you the module Safe Mode

Página 38 - Test I/O

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-14 ATTENTION There are two situations that will prompt the Active Ethernet modular I/O

Página 39

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-15Adaptor Settings Tab (Administrator) There are five parts in this TAB: Password, Mana

Página 40 - Network Tab (Administrator)

I/O Module... 4-6 System Mana

Página 41 - Watchdog Tab (Administrator)

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-16Network Tab (Administrator) The Network tab is where you configure IP settings, Modbu

Página 42 - Active Tags (Administrator)

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-17Firmware Update Tab (Administrator) The ioLogik E4200 supports remote firmware update

Página 43

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-18After the Watchdog is enabled, the ioLogik E4200 will enter safe status if the networ

Página 44

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-19 ATTENTION When ioLogik E4200 is in safe mode, user can not start Click&Go logi

Página 45

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-20Click&Go Logic Tab (Administrator) The Click&Go logic tab is where administra

Página 46 - Using ioEventLog

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-21You must use “ik4200.txt” as the destination filename when copying a configuration fi

Página 47 - Main Menu

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-22Using ioEventLog Installing ioEventLog ioEventLog is a Windows utility that can be us

Página 48 - Connection

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-23Basic Functions ioEventLog is installed along with ioAdmin from the Document and Soft

Página 49

ioLogik Active Ethernet I/O Family User’s Manual Utilities 3-24Connection Checking Connected Devices You can see which I/O devices are already conne

Página 50 - Overview for ioLogik E4200

44 Chapter 4. Using the Built-in Web Console This chapter introduces built-in web console when monitoring the ioLogik Active Ethernet modular I/O

Página 51 - Overview

11 Chapter 1. Introduction The ioLogik Active Ethernet modular I/O family of advanced, slice-type network I/O products with local intelligence can

Página 52 - Network Settings

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-2Overview for ioLogik E4200 The ioLogik Active Ethernet modular I/

Página 53 - Route Table

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-3Entering the Web Console Modular ioAdmin utility is the main conf

Página 54 - I/O Module

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-4Basic Settings On the Basic Settings page, you may set the ioLogi

Página 55 - System Management

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-5Ethernet Configuration On the Ethernet Configuration page, you ma

Página 56 - Network Connection

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-6I/O Module On this page, you can find the modules you installed i

Página 57 - Import System Config

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-7System Management Accessible IP Settings You may add a specific a

Página 58 - Change password

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-8SNMP Agent On the SNMP Agent page, you may enable SNMP and set th

Página 59 - Save/Restart

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-9Firmware Update On the Firmware Update page, you may load new or

Página 60 - Click&Go Introduction

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-10Export System Config On the Export System Config page, you may c

Página 61

ioLogik Active Ethernet I/O Family User’s Manual Using the Built-in Web Console 4-11Load Factory Default This function will reset all of the ioLog

Página 62 - Click&Go Logic Basics

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-2ioLogik Active Ethernet Modular I/O System Overview The ioLogik Active Ethernet mod

Página 63 - Working with Rules

55 Chapter 5. Click&Go Introduction Click&Go logic was developed by Moxa to provide an easy way to set your ioLogik E4200 for Active I/O m

Página 64 - Define Global Variables

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-2Overview Everybody can be a programmer! Moxa’s Click&Go event-base

Página 65 - Internal Register Settings

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-3Features Click&Go logic’s key features are as follows: 80 Rules

Página 66 - SNMP Trap Server

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-4 1. Global Variables: In this field, you can assign variables for all

Página 67 - E-Mail Server

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-5 ATTENTION The unit of measurement and alias name of I/O channel is d

Página 68 - SMS Phone Number Book

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-6Internal Register Settings Internal Register is a flag that can be use

Página 69 - IF/THEN/ELSE Statement

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-7Timer Settings The Timer function allows users to delay an action, to

Página 70

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-8E-Mail Server The E-mail Server configures the parameters of the targe

Página 71 - THEN/ELSE Actions

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-9Active Message Settings Active Message Settings configures one or more

Página 72

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-10IF/THEN/ELSE Statement Rules are the building blocks of your ioLogi

Página 73 - SNMP Trap

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-3Product Features Slice Form Factor, High Density Modular I/O The ioLogik E4200’s co

Página 74 - Active Message

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-11IF conditions can be specified as follows: DI DI refers to the status

Página 75 - Short Message Service (SMS)

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-12Timer The Timer function can be used to control the timing of a logic

Página 76 - Ruleset Management Bar

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-13DO DO refers to the action of controlling the local digital output ch

Página 77 - Ruleset Import/Export

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-14SNMP Trap SNMP Trap function sends an SNMP trap to one or more IP des

Página 78 - Pinouts and Cable Wiring

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-15Active Message In response to a proper IF condition, the Active Messa

Página 79 - Using Modbus/TCP

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-16E-mail The E-mail function sends a customizable e-mail to one or more

Página 80

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-17Working with Click&Go Rulesets Activating the Ruleset Download,

Página 81

ioLogik Active Ethernet I/O Family User’s Manual Click&Go Introduction 5-18Ruleset Import/Export Although rulesets alone cannot be imported and

Página 82

AA Appendix A. Pinouts and Cable Wiring Port Pinout Diagrams Ethernet Port Pinouts 18 Pin Signal 1 Tx+ 2 Tx- 3 Rx+ 6 Rx- Serial Port Pinouts RS-2

Página 83

BB Appendix B. Using Modbus/TCP ioLogik E4200 Modbus map has three categories: a. IO image map: for all input and output channels which installed

Página 84

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-4Package Checklist Each network adaptor and I/O module is packed securely in a small

Página 85

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-2324628 0x6033 1 word Ethernet Interface-1 speed, 0x10(10Mbps) or 0x100(100Mbps) 3

Página 86

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-3324684 0x606B 1 word Reserved 324685 0x606C~0x607C 16 word Moxa code of each att

Página 87

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-4Word 0 Hi byte = 192 Word 0 Lo byte = 168 Word 1 Hi byte = 15 Word 1 Lo byte = 1 G

Página 88

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-5424635 0x603A 1 word Host connection loss Time Out value (enter safe state) 424

Página 89 - Fixed mode (default mode):

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-6434423 0x8676 1 word Internal Register 01 Value (Power On) 434424 0x8677 1 wo

Página 90 - Module Configuration Map

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-7434458 0x8699 1 word Internal Register 36 Value (Power On) 434459 0x869A 1 wo

Página 91 - DI Module Configuration Map:

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-8434493 0x86BC 1 word Internal Register 71 Value (Power On) 434494 0x86BD 1 wo

Página 92 - AI Module Configuration Map:

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-9434971 0x889A 1 word Internal Register 26 Value (Working) 434972 0x889B 1 wor

Página 93 - TC Module Configuration Map:

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-10435006 0x88BD 1 word Internal Register 61 Value (Working) 435007 0x88BE 1 wo

Página 94 - Function 8

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-11The addressing of I/O image Map Modular ioAdmin allocated the I/O channels by fou

Página 95 - CGI Commands

ioLogik Active Ethernet I/O Family User’s Manual Introduction 1-5Analog Input Modules M-3402 4 analog inputs, 4 to 20 mA, 12-bit, removable termi

Página 96

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-12Dynamic mode: To improve the fragment memory size and get higher efficiency perfo

Página 97 - Used Network Port Numbers

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-13DO Module Configuration Map: N stands for channel quantity Input register map(R)

Página 98 - SNMP MIB File

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-14AO Module Configuration Map: N is stand for channel quantity Input register map(R

Página 99

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-15TC Module Configuration Map: N is stand for channel quantity Input register map(R

Página 100

ioLogik Active Ethernet Modular User’s Manual Using Modbus/TCP B-16Internal Registers Please refer to the exported Modbus address file for detail. F

Página 101

CC Appendix C. CGI Commands Using a web browser or standard HTTP protocol will make it easier for a Security SCADA system to monitor and control a

Página 102

ioLogik Active Ethernet Modular User’s Manual CGI Commands C-2Use the following syntax to set parameters. Start with the ioLogik’s IP or URL followe

Página 103 - Factory Default Settings

DD Appendix D. Used Network Port Numbers E4200 Network Port Usage: Port Type Usage 80 TCP Web Server 502 TCP Modbus Communication 161 TCP SNMP 68

Página 104

EE Appendix E. SNMP MIB File Modular ioAdmin can export MIB file according to current module combination dynamically. The ioLogik E4200 has built-

Página 105 - Appendix G. FCC

ioLogik Active Ethernet Modular User’s Manual SNMP MIB File E-2System MIB Interfaces MIB IP MIB ICMP MIB ifInUnknownProtos ipReasmFails IcmpOutT

Comentários a estes Manuais