NPort 5100 Series Web Console Configuration
5-18
Connection control
Setting Factory Default Necessity
Startup/None, Any
Character/None,
Any
Character/Inactivity
Time,
DSR ON/DSR OFF,
DSR
ON/None,
DCD ON/DCD OFF,
DCD
ON/None
Startup/None Required
The meaning of each of the above settings is given in the table below. In general, both the Connect condition
and Disconnect condition are given.
Connect/Disconnect Description
Startup/None
(default)
A TCP connection will be established on startup, and will remain active indefinitely.
Any Character/None A TCP connection will be established when any character is received from the serial
interface, and will remain active indefinitely.
Any Character/
Inactivity Time
A TCP connection will be established when any character is received from the serial
interface, and will be disconnected when the Inactivity time out is reached.
DSR On/DSR Off A TCP connection will be established when a DSR “On” signal is received, and will
be disconnected when a DSR “Off” signal is received.
DSR On/None A TCP connection will be established when a DSR “On” signal is received, and will
remain active indefinitely.
DCD On/DCD Off A TCP connection will be established when a DCD “On” signal is
received, and will
be disconnected when a DCD “Off” signal is received.
DCD On/None A TCP connection will be established when a DCD “On” signal is
received, and will
remain active indefinitely.
UDP Mode